Technical Requirements for Thermocouple Calibration Furnace

Release time:2023-1-12    This article is read 4235 Times

When calibrating thermocouples, thermocouple calibration furnace and portable dry block furnace are generally used. According to different heating element materials, thermocouple calibration furnaces used in laboratories can generally be divided into nickel-chromium wire calibration furnaces and iron-chromium-aluminum wire calibration furnace , Platinum rhodium wire calibration furnace, molybdenum wire calibration furnace, silicon carbide calibration furnace, tantalum tube furnace and tungsten tube furnace.

thermocouple calibration furnace


Technical Requirements for Thermocouple Calibration Furnace

1. It needs to meet the temperature of the test point of the thermocouple being tested, and has a certain service life. For example, the platinum rhodium 10-platinum thermocouple regulation requires that the calibration point temperature is 1084.62°C, so the long-term use temperature of the calibration furnace is not lower than 1100°C; the calibration platinum rhodium 30-platinum rhodium 6 thermocouple regulation requires the calibration point temperature to be 1500°C, Therefore, the long-term use temperature of the calibration furnace is required to be not lower than 1500°C; the calibration point temperature of the K-type thermocouple is 1200°C, so the long-term use temperature of the calibration furnace is required to be 1200°C.


2. In order to reduce the heat conduction error and ensure that the thermocouple has a certain insertion depth during the verification, the material, diameter and length of the furnace will be required. For example: the length of the verification furnace requires about 600mm, and the interior is composed of three layers of alumina tube: winding wire The size of the tube is Φ40mm*50mm*600mm; the size of the outer tube is Φ70mm*80mm*600mm; the size of the inner tube of the verified precious metal thermocouple is about Φ15mm*20mm*600mm; the size of the inner tube of the verified cheap metal thermocouple can be determined according to the specific situation. When verifying short thermocouples of 200-700mm, the length of the verification furnace is about 300mm. Furnace material, diameter and length can be customized according to needs.


3. In order to ensure the quality of the calibration, the temperature distribution of the temperature field of the calibration furnace along the axial direction should be high in the middle and low at both ends. The highest temperature point deviates from the geometric center position, and the calibration furnace for platinum-rhodium series thermocouples shall not exceed 20mm, and there is a uniform temperature field with a temperature gradient of 0.5°C/10mm within 200mm of the highest point; For 200-700mm short thermocouple calibration furnace and base metal thermocouple calibration furnace, the temperature point deviation from the geometric center shall not exceed 10mm.


4. The atmosphere in the calibration furnace should meet the requirements of the thermocouple to be tested and the components of the calibration furnace.


5. In order to improve the verification efficiency and facilitate operation, the thermocouple verification furnace is required to heat up quickly and have good heat preservation performance.

Technical Requirements for Thermocouple Calibration Furnace
  • Online message

  • Your name
    Your title must be filled
  • Cellphone number
    Mobile phone number is required
  • whatsapp/wechat
    Optional
  • Type of consultation
    Required, please select the type of consultation
  • Consultation content
    Required, what is the content you want to consult?
  • Verification code: Please fill in the calculation result.
Previous:Common Methods of Thermocouple Calibrationnext:What can DTHTH high temperature & high humidity calibration chamber be used to do?

Contact us

DEARTO QR codeHeadquarter Address Tai'an High-tech Development Zone,  Shandong Province 
Telephon :+86 0538-5089056  +86 13953856217 
Fax : +86 0538-5059718 
After sale:+86 0538-5050959
Website : www.tadt.com.cn 
E-mail   :  tadtzdh@dearto.cn

Copyright? Tai'an Detu Automation Instrument Co., Ltd.             Lu ICP 14024757-1           Business license inquiry

主站蜘蛛池模板: 国产成人综合亚洲欧美在| 毛片一级在线| 欧美成人h精品网站| 欧美a在线| 日本少妇又色又爽又高潮| 国产簧片免费在线播放| 国产无码性爱一区二区三区| h网站在线播放| 91久久夜色精品国产网站| 青草国产在线视频| 亚洲电影天堂在线国语对白| 女人18一级毛片免费观看| 国产成人亚洲毛片| 欧美日本在线观看| 美女扒开下面流白浆在线试听 | 91九色视频网| 噜噜噜久久| 精品国产Av电影无码久久久| 色综合色国产热无码一| 波多野结衣二区| 全免费a级毛片免费看不卡| 成人午夜视频网站| 狠狠ⅴ日韩v欧美v天堂| 国产成人夜色91| 亚洲丝袜中文字幕| 青草视频免费在线观看| 久久综合五月婷婷| 91人人妻人人做人人爽男同| 亚洲丝袜中文字幕| 亚洲婷婷在线视频| 亚洲天堂区| 青草视频在线观看国产| 少妇被粗大的猛烈进出免费视频| 久久久久人妻一区精品色奶水 | 精品国产中文一级毛片在线看| 精品成人一区二区三区电影 | 亚洲色欲色欲www在线观看| 精品一区国产精品| 中文字幕精品一区二区三区视频| 欧美日本一区二区三区免费| 米奇精品一区二区三区| 91久久夜色精品国产网站| 免费视频在线2021入口| 九色综合伊人久久富二代| 国产精品伦视频观看免费| 免费A级毛片无码免费视频| 欧美午夜在线观看| 国产精品国产三级国产专业不| 国产草草影院18成年视频| 三级视频中文字幕| 天堂成人av| 国产一级视频在线观看网站| 免费无码又爽又刺激高| h视频在线观看网站| 青青国产视频| 亚洲无码高清一区二区| 全部毛片免费看| 久久久亚洲色| 亚洲男人天堂久久| 久久久久无码国产精品不卡| 久久香蕉国产线看精品| 日韩视频免费| 亚洲综合久久成人AV| 亚洲高清日韩heyzo| 无码中字出轨中文人妻中文中| 欧美日韩资源| 午夜福利网址| 亚洲永久免费网站| 91视频首页| 久久九九热视频| 亚洲欧美不卡视频| 幺女国产一级毛片| 国产福利影院在线观看| 色香蕉影院| 老色鬼欧美精品| 伊人丁香五月天久久综合| 久久精品波多野结衣| 97se亚洲综合在线| 2021无码专区人妻系列日韩| 欧美精品一区在线看| 亚洲三级视频在线观看| 国产成人精品免费av|